Carbon methodology · v2.0

How carbon intensity
is estimated

A transparent, reproducible estimate—not a claim of meter-level precision. Gridmix Atlas combines reported generation with a fixed lifecycle factor for each fuel.

THE CALCULATION
Σ (generationfuel × factorfuel)÷Σ generationall fuels= gCO₂e/kWh

Each MW observation is multiplied by its interval duration to get MWh. Storage discharge and imports are excluded from both the generation denominator and emissions numerator. This is a domestic generation estimate, not the carbon content of consumed electricity. Negative generation is excluded from the carbon calculation. Daily MWh totals are already energy and are not multiplied by 24 again.

Factor library

Lifecycle emission
factors

Factors are central estimates in grams of CO₂-equivalent per kWh. They include lifecycle effects for consistency across fossil, renewable, and nuclear generation.

Fuel familyMapped labelsgCO₂e/kWhBasis
WindWind11Lifecycle
NuclearNuclear12Lifecycle
HydroHydro / Large Hydro / Small hydro24Lifecycle
GeothermalGeothermal38Lifecycle
SolarSolar45Lifecycle
BiomassBiomass / Biogas / Bioenergy230Lifecycle
Natural gasNatural Gas / Gas490Lifecycle
OilOil650Lifecycle
Other fossilOther Fossil700Conservative blend
CoalCoal / Coal and Lignite820Lifecycle
Storage & trade

Energy moving through the system

Charging appears below zero and discharging above it. Daily totals preserve both directions before aggregation, where source resolution permits. Net interval readings cannot reveal simultaneous charging and discharging at different devices. We do not infer state of charge, round-trip efficiency, or the fuel origin of imported electricity.

EIA interchange is sign-reversed to make imports positive. CAISO legacy Other is a provisional storage proxy only where dedicated storage fields are absent. Other can also contain masked or unknown generation, so the proxy is not a verified battery-only measurement.

EIA reporting definitions
01

Production-based

The estimate follows electricity reported inside the selected system. It is not a consumption-based flow model and does not trace imported power to its originating plant.

02

Average, not marginal

This is the weighted average of the visible mix. It does not estimate which generator would respond to one additional kWh of demand.

03

Storage accounting

Storage is excluded from the domestic-generation carbon calculation, not treated as a zero-carbon fuel. Charging emissions remain with the original generation. We do not estimate storage discharge intensity without charge-source tracing.

04

Trade stays separate

Country fuel shares describe domestic generation. Reported net imports and exports are shown alongside the mix, but imported power is not assigned a fuel unless its origin is known. Net trade is not the same as gross cross-border flows.

Primary references